Drop Weight Impact Testing Machine
  • Application: 

    DWTI series drop weight impact testing machine is suitable for conducting drop-weight test to detect the anti-impact performance of special products, like metal, pipes, boots, plastics and any other materials. 

    Non-instrumented tester can only test the performance of faulty or not. With instrumented system, it can be obtained the detailed impact procedure as the curve of Force-Time, Energy-Time, Force-Displacement, Energy-Displacement, and speed etc..

    It is widely used in factories, plastics, engineering, universities, R&D etc..


    Applied standards:

    ASTM E208, GB6803

    • ASTM D256(Izod), D6110 (Charpy), D950, D1822, D2444, D5420, D3763, D4508, D4812, D5628, E23(Izod, Charpy), E208, E436, E604.

    • ISO179 (Chapry), ISO180 (Izod), 148 (Charpy), 7765-2, 6603-1, 6603-2, 179-2, 3127.

    • Others: DIN 53453, DIN51222, Boeing 7260, GM9300P, GM9904P, GM4349M, EN10045, JIS K7111(Charpy), NASA STI, API-SL3, Ford ESBM16J14-A, Blat 1-2, NFT51-118, UNI7448.

    • Customer’s special requirement especially for the structured instrumented test.

  • ModelDWTT- 20000DWTT- 30000DWTT- 40000DWTT- 50000DWTT- 80000DWTT- 100000
    Max. Energy (J)2000030000400005000080000100000
    Max. Lifting (mm)300028002500200030003000
    Max. Impact Velocity (m/s)7.67.4777.57.5
    Curvature Radius of Weight (mm)R25R25R25.4±2.5R25R25R25
    Curvature Radius of Anvil (mm)R25R25R14.3±1.59R15.5R15R15.5
    Hardness of Weight and Anvil≥HRC58≥HRC58HRC58-65HRC58-65HRC58-65HRC58-65
    Distance between Supports (mm)254254254254254254
    Centering Deviation of Specimen   (mm)≤±1≤±1≤±1≤±1≤±1≤±1
    Indicating Deviation of Lifting   (mm)≤±1≤±1≤±1≤±1≤±1≤±1
    of the Load Frame (mm)550055005700570068007000
    Weight (kg)560056009500178001800024000


    ModelDWTI 300DWTT 750/1000DWTI 1500/2000DWI-400
    Max. energy (J)300750/10001500/2000400
    Max. lifting height (mm)1000160020002000
    Max. impact velocity (m/s)4.4±0.2m5.56/
    Hammer mass range (kg)20.0065.002.00-70.000.25-16
    Support column spacing: transverse×depth (mm)590×490/
    Hardness of anvil & hammerHRC50~HRC60/


    TE can supply with customized special design to meet various kinds of testing requirements